Guidance 4D probe; recognize the probe via the ID code; swap the 4D travel signal via the electrical relay to produce the 4D probe perform Typically. four.two.two Key board The leading board might be divided into two sections: front-conclude of the main board and back-close of the most crucial board.
Dengan obshape baru yang cerdas dan desain layar penuh, mobilitas yang ditingkatkan, dan pengoperasian yang lebih nyaman, sistem yang andal dan terjangkau ini akan meningkatkan praktik umum dan sangat cocok untuk berbagai kebutuhan klinis.
Evaluating patients in now’s demanding environment needs impressive technological know-how that permits clinicians to help make fast and self-confident diagnoses. The flexibility of your DP-50 expands your scientific utility though helping to increase affected person care.
The person is not really permitted to open the covers and panel in the system, neither NOTE: gadget disassemble is permitted. To ensure the process efficiency and safety, only Mindray engineers or engineers licensed by Mindray can carry out routine maintenance.
Uncover greater diagnostic information and facts via extended see in the anatomical structure on all convex probes.
Return for the technique preset interface. The option standing changes into Uninstalled. The uninstalling purpose is unique to inner people.
Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi detail mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.
S. must present the Division by having an e-mail handle if they've got 1. The e-mails supplied can be used for official conversation Together with the licensee. Nonetheless e mail addresses are general public record. If you do not want to produce a private handle, make sure you present the Office with the e mail tackle which may be built available to the public. To determine Should you be a licensee underneath Chapter 455, File.S., you should Click the link . Product Acceptance Accepts:
Perform: Around the again-conclusion of the most crucial board, a Specific check IC is used to watch signal voltages and clock battery power which are delivered to the key board by the main unit box ability provide module.
iZoom™ enables correct viewing of image from length iWorks™ Protocol helps standardize workflow and reduce exam occasions
Cookies are important to the correct operating of the web page. To improve your encounter, we use cookies to remember log-in information and supply safe log-in, gather figures to optimize site operation, and produce information tailor-made towards your pursuits.
Untuk memenuhi janji menyediakan perawatan kesehatan berkualitas tinggi dan efektif, Mindray terus mengembangkan kemajuan teknologi medis untuk meningkatkan kualitas perawatan pasien. Dilengkapi dengan PW Doppler dan kemampuan 3D/4D, DP-50Exp menawarkan lebih dari yang Anda Dp50rb login harapkan.
Immediately after replacing the CPU module, crucial file has to be generated Once more based on the new MAC tackle and written into HDD in the device. Or else, the configuration operate with the product will likely be dropped. Immediately after eradicating the CPU module, Take away panhead screws with washers (twelve M3X6) mounted on the leading device box, you will take off the board. Webpage 118 Figure eight-29 Disassemble the User interface Assembly (one) Hold the upper fringe of control panel assembly, and open up up the control panel. Determine 8-30 Disassemble the Control Panel Assembly (two) Immediately after taking away one particular countersunk head self-tapping screw PT3X10 mounted within the user interface and acquire out the plug in the keyboard and the primary device connecting cables, you could possibly take away the user interface assembly.
General performance Examination five.five.one Check System Resolution Detection depth Geometric Situation Precision Blackout place take a look at Record the exam illustrations or photos five.five.two Test Articles The graphic used here is only for reference, stick to the graphic outcome in the actual NOTE: circumstance. Necessities: Display screen: established the distinction and brightness for the medical software value (or maybe the default status) Operation atmosphere: dark room, simulating the clinical software natural environment. Site 76 In problem that the transverse resolution tests targets are horizontally shown, document the minimal length of two targets that may be Evidently acknowledged. Repeat the Procedure higher than for that transverse resolution testing targets at other depths. As demonstrated in figure underneath. Axial resolution ... Site 77 When using the convex probe, hold the transverse resolution tests targets to NOTE: be shown close to the midline. When employing a linear probe with steer operate, don't turn on the steer functionality when complete the transverse resolution test. Zoom within the region where the targets Positioned if vital. The diameter in the focus on point at a certain depth is equal on the transverse resolution within the depth. Webpage 78 5.
Mindray respects your privacy. We use cookies for several different needs, which include Web site performance, enhancing your expertise of our Internet site, setting up integration with social websites and helping goal our promoting.
Take note: Make certain that you can pull out and force in to the IO board sockets vertically when pulling out and assembling the IO board assembly over the place with the deal with. Clear away panhead screws with washers M3X6 (four) utilized to protected the IO board, and afterwards you can consider out the IO board. Site 116 Take out panhead screws with washers (two M3X6) that are mounted on the most crucial unit, get out the upper baffle then pull out two cables connecting the leading board to the ability module assembly.